Home / Browse projects / Solapur, Maharashtra / Ray Nagar Housing Project
Ray Nagar Housing Project
By Vasant Vihar Realty Pvt Ltd
RG-MH-91792 · RERA P52600017938 · Last updated on MahaRERA portal: 14 May 2024
Source: official MahaRERA filing
Red flags
- No red flags in this filing
Clear
- No litigation declared
- No complaints on record
- Completion date never moved
- Separate project account declared
- Allotment letter follows the model form
- Recorded completed on MahaRERA
Nothing adverse is on this record. The buyer report still reads the filed documents themselves, and places this filing against the promoter's 1 other registration and every project registered within 2 km.
See what the report covers Free either way: or have every new Solapur registration emailed to you, free during the pilot beta.Saved. When you are ready to decide, the Rs 499 buyer report reads the fine print for you.
Ray Nagar Housing Project is a Mixed project by Vasant Vihar Realty Pvt Ltd in Solapur, Maharashtra, registered with MahaRERA as P52600017938 on 27 Sep 2018. The registration is recorded completed; possession was promised by 30 Dec 2025. 0 of the 1 unit on this registration is recorded sold or booked, and 3893 of 4961 construction stages are filed complete.
At a glance
Project
- NameRay Nagar Housing Project
- TypeMixed
- Location
- Kumbhari to Doddi road
- Kumbhari
- Solapur South
- Solapur
- 413006
- Pincode413006
- MapView location on Google Maps (as filed on RERA)
- RERA no.P52600017938
- ReraGenie IDRG-MH-91792
Builder
- NameVasant Vihar Realty Pvt Ltd
- Entity typeCompany
- DirectorNILIMA ANIL JADHAV
- Other registrations1 more →
- Completed1 of 2
Key dates
Key facts
Registration and timeline
- StatusCompleted
- Registered on27 Sep 2018
- Promised completion30 Dec 2025
- Revised completionNone
- Buildings452 building records
- Documents filed254 files
Current status
Figures as on 14 May 2024, this project's latest MahaRERA filing.
Buildings and wings, as sanctioned
| Building | Wing | Floors sanctioned | Habitable floors | Residential units | Other units | Total |
|---|---|---|---|---|---|---|
| Gat No-722/2F/723, Bldg No-B1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 722/2F/723, Bldg No-B2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg no -A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -B1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -726/1 and 726/2, Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -726/1 and 726/2, Bldg No -A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -728/1, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No - A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 728/1, Bldg No -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No A16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A17 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -728/1, Bldg No -A18 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A19 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A20 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A21 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg no -A22 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No A23 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A24 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A25 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A26 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A27 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A28 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No-A29 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A30 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A31 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No A32 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/1, Bldg No -A33 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-728/2, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No-A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO -728/2, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No -A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO 728/2, Bldg NO -A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No-A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No-A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2, Bldg No-A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat vNo -729/1, ,Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No-A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bldg No-A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -729/1, Bld No-A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2P, Bldg No-A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2P, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2P, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -728/2P, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 728/2P, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 728/2P, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -845/5, 845/6, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -845/5, 845/6, Bldg No-A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -845/5, 845/6, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO -845/5, 845/6, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -845/5, 845/6, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -845/5, 845/6, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -845/5, 845/6, Bldg No -A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No-A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No-A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707,Bldg No-A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No-A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No-A16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A17 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A18 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A19 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707 Bldg No -A20 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A21 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No-A22 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A23 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A24 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No-A25 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A26 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No-A27 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO -707, Bldg No -A28 | NA | 3 | 0 | 0 | 0 | 0 |
| GAt No -707, Bldg No -A29 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A30 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -707, Bldg No -A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No - A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No- A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697 ,Bldg No -A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| gat No -697, Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO -697, Bldg No -A16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO -697, Bldg No A17 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A18 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No-A19 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No-A20 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A21 | NA | 3 | 0 | 0 | 0 | 0 |
| gat No -697, Bldg No -A22 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No-A23 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A24 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -697, Bldg No -A25 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -721/1, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| gat No -721/1, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No --721/1, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No- A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/1, Bldg No -A16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg no -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No-A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg No -A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg no -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -721/3, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| gat No -721/3, Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -721/3, Bldg no -A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -721/3, Bldg no -A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -721/3, bldg No -B1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1, Bldg No -A1 | NA | 3 | 0 | 0 | 0 | 0 |
| gat No -755/1, Bldg No-A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1, Bldg No-A3 | NA | 3 | 0 | 0 | 0 | 0 |
| gat No -755/1, Bldg No-A4 | NA | 3 | 0 | 0 | 0 | 0 |
| gat no -755/1, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no -755/1, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1, Bldg No-A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1, bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1, Bldg No-A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1, Bldg No -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -755/1,Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-755/1, Bldg No -A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-755/1,Bldg No -A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-755/1, Bldg No -A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/D/1, Bldg No-A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No -A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D, Bldg No -A8 | NA | 3 | 0 | 0 | 0 | 0 |
| gat No-764/1A/1B/1C/1D,1, Bldg No -A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO -764/1A/1B/1C/1D/1, Bldg No -A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A17 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A18 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A19 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 764/1A/1B/1C/1D/1, Bldg No -A20 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A21 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A22 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A23 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A24 | NA | 3 | 0 | 0 | 0 | 0 |
| Gta nO -764/1A/1B/1C/1D/1, Bldg No -A25 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D, Bldg No -A26 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A27 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A28 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No -A29 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A30 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat NO -764/1A/1B/1C/D/1, Bldg No -A31 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A32 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A33 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A34 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A35 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No -A36 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A37 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No-A38 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No -A39 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A40 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1a/1b/1c/1d/1, Bldg No -A41 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No-A42 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No A 43 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No -764/1A/1B/1C/1D/1 Bldg No -A44 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No -A45 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-764/1A/1B/1C/1D/1,Bldg No -B1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 963/1, 963/2, 963/3, 977/1, Bldg No 1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 845/5, 845/6 Bldg No - A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 845/5, 845/6 Bldg No - A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 845/5, 845/6 Bldg No - A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 845/5, 845/6 Bldg No- A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 845/5, 845/6 Bldg No - A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 845/5, 845/6 Bldg No- A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 845/5, 845/6 Bldg No- A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 845/5, 845/6 Bldg No- A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3, 977/1 Bldg No- 2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No-3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No - 4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No 6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 17 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 18 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 19 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 20 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 21 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 22 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 23 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 24 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 25 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No - 26 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 27 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 28 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 29 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 30 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 31 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 32 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 33 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 34 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 35 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 36 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 37 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 38 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 39 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 40 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No - 8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg no- 11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No - 12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No - 14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg no - 15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 17 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 18 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 19 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 20 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg no- 21 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no- 981/1,982/1,982/2 Bldg No- 22 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 23 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg no- 24 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 25 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 26 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 27 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 28 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 29 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 30 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 31 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 32 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 33 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 34 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 35 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 36 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 37 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 38 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 39 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 40 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 41 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 42 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 43 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 44 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 45 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 46 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 47 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 48 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 49 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 50 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 51 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 52 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 53 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 54 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 55 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 56 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 57 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 58 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 59 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 60 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 61 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 62 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 981/1,982/1,982/2 Bldg No- 63 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 64 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 65 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 66 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 981/1,982/1,982/2 Bldg No- 67 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 68 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 69 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 70 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 71 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 72 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 73 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 74 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 75 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 76 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat no- 981/1,982/1,982/2 Bldg No- 77 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 78 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 79 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 80 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 81 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 981/1,982/1,982/2 Bldg No- 82 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 979/1 Bldg No- 2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 979/1 Bldg No- 6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 979/1 Bldg No- 7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 16 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 17 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 18 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 979/1 Bldg No- 19 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 20 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 21 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 22 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 23 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 24 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 25 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 26 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 27 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 28 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 29 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 30 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 979/1 Bldg No- 31 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-710/1 Bldg No- A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-710/1 Bldg No- A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No - 710/1 Bldg No- A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No - A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/1 Bldg No- A15 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No-710/2 Bldg No- A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 710/2 Bldg No- A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 710/2 Bldg No- A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A1 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A2 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A3 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A4 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A5 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A6 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A7 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A8 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A9 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A10 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A11 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A12 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A13 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A14 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No- 755/2 Bldg No- A15 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-435 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-436 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-437 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-438 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-439 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-440 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-441 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-442 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-443 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-444 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-445 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-446 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-447 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-448 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-449 | NA | 3 | 0 | 0 | 0 | 0 |
| L19-450 | NA | 3 | 0 | 0 | 0 | 0 |
| Gat No 722-A3 GF-101 TO 112 FF-201 TO 212 SF- 301 TO 312 | NA | 3 | 0 | 0 | 0 | 0 |
| L-11-233 | NA | 3 | 0 | 0 | 0 | 0 |
The full filing
Everything below is from the project's own MahaRERA filing, free to read. The Rs 499 buyer report reads the filed documents themselves and puts the findings in plain language.
Construction progress by building20
As on 14 May 2024, the date of the latest filing. The RERA activity checklist for each building, from the promoter's latest quarterly progress filing. These are the promoter's own figures, not an independent inspection. The count above covers all 453 buildings; the table lists the first 20.
3893 of 4961 construction stages are filed complete across 453 buildings. The stage furthest along is Internal walls, at 60%.
Gat No-722/2F/723, Bldg No-B182%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A182%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A282%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A382%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A482%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A582%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A682%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A782%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-A882%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No- 722/2F/723, Bldg No-B282%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A182%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A282%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A382%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A482%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A582%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A682%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg no -A782%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -B182%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A882%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Gat No -726/1 and 726/2, Bldg No -A982%
| Activity | Progress |
|---|---|
| Excavation | 100% |
| Basement (if any) | 100% |
| Podiums (if any) | 0% |
| Plinth | 100% |
| Stilt Floor | 0% |
| Slabs of Super Structure | 100% |
| Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises | 100% |
| Sanitary Fittings within the flats / premises | 100% |
| Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks | 100% |
| External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing. | 100% |
| Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. | 100% |
Progress on shared amenities15
As on 14 May 2024, the date of the latest filing. Lifts, roads, water and the other shared works, from the same quarterly filing, and reported by the promoter rather than inspected.
| Common facility | Proposed | Progress |
|---|---|---|
| Internal Roads & Footpaths | Yes | 100% |
| Water Supply | Yes | 100% |
| Sewerage (Chamber, Lines, Septic Tank , STP) | Yes | 100% |
| Storm Water Drains | No | Not applicable |
| Landscaping & Tree Planting | No | Not applicable |
| Street Lighting | No | Not applicable |
| Community Buildings | No | Not applicable |
| Treatment And Disposal Of Sewage And Sullage Water | No | Not applicable |
| Solid Waste Management And Disposal | Yes | 100% |
| Water conservation /Rain water harvesting | Yes | 100% |
| Energy managemcnt | No | Not applicable |
| Fire protection and fire safety requirements | No | Not applicable |
| Electrical meter room, sub-station, receiving station | No | Not applicable |
| Aggregate area of recreational Open Space | No | Not applicable |
| Open Parking | Yes | 100% |
Parking filed15994
Slots recorded per building wing in the filing. MahaRERA does not publish a two wheeler or four wheeler split, visitor parking, or the sanctioned allotment, so this is provision as filed and not a comparison against the approved plan.
| Building | Open Space | Total |
|---|---|---|
| Gat No-722/2F/723, Bldg No-B1 | 24 | 24 |
| Gat No- 722/2F/723, Bldg No-A1 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-A2 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-A3 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-A4 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-A5 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-A6 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-A7 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-A8 | 36 | 36 |
| Gat No- 722/2F/723, Bldg No-B2 | 24 | 24 |
| Gat No -726/1 and 726/2, Bldg No -A1 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A2 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A3 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A4 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A5 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A6 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg no -A7 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -B1 | 24 | 24 |
| Gat No -726/1 and 726/2, Bldg No -A8 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A9 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A10 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A11 | 36 | 36 |
| Gat No -726/1 and 726/2, Bldg No -A12 | 36 | 36 |
| Gat no -726/1 and 726/2, Bldg No -A13 | 36 | 36 |
| Gat No -728/1, Bldg No -A1 | 36 | 36 |
| Gat No -728/1, Bldg No -A2 | 36 | 36 |
| Gat No -728/1, Bldg No -A3 | 36 | 36 |
| Gat no -728/1, Bldg No -A4 | 36 | 36 |
| Gat No -728/1, Bldg No -A5 | 36 | 36 |
| Gat No -728/1, Bldg No -A6 | 36 | 36 |
| Gat No -728/1, Bldg No -A7 | 36 | 36 |
| Gat No -728/1, Bldg No -A8 | 36 | 36 |
| Gat No -728/1, Bldg No - A9 | 36 | 36 |
| Gat No - 728/1, Bldg No -A10 | 36 | 36 |
| Gat No -728/1, Bldg No -A11 | 36 | 36 |
| Gat No -728/1, Bldg No -A12 | 36 | 36 |
| Gat No -728/1, Bldg No -A13 | 36 | 36 |
| Gat No -728/1, Bldg No -A14 | 36 | 36 |
| Gat No -728/1, Bldg No -A15 | 36 | 36 |
| Gat No -728/1, Bldg No A16 | 36 | 36 |
| Gat No -728/1, Bldg No -A17 | 36 | 36 |
| Gat no -728/1, Bldg No -A18 | 36 | 36 |
| Gat No -728/1, Bldg No -A19 | 36 | 36 |
| Gat No -728/1, Bldg No -A20 | 36 | 36 |
| Gat No -728/1, Bldg No -A21 | 36 | 36 |
| Gat No -728/1, Bldg no -A22 | 36 | 36 |
| Gat No -728/1, Bldg No A23 | 36 | 36 |
| Gat No -728/1, Bldg No -A24 | 36 | 36 |
| Gat No -728/1, Bldg No -A25 | 36 | 36 |
| Gat No -728/1, Bldg No -A26 | 36 | 36 |
| Gat No -728/1, Bldg No -A27 | 36 | 36 |
| Gat No -728/1, Bldg No -A28 | 36 | 36 |
| Gat No -728/1, Bldg No-A29 | 36 | 36 |
| Gat No -728/1, Bldg No -A30 | 36 | 36 |
| Gat No -728/1, Bldg No -A31 | 36 | 36 |
| Gat No -728/1, Bldg No A32 | 36 | 36 |
| Gat No -728/1, Bldg No -A33 | 36 | 36 |
| Gat No -728/2, Bldg No -A1 | 36 | 36 |
| Gat No-728/2, Bldg No -A2 | 36 | 36 |
| Gat No -728/2, Bldg No -A3 | 36 | 36 |
| Gat No -728/2, Bldg No -A4 | 36 | 36 |
| Gat No -728/2, Bldg No-A5 | 36 | 36 |
| Gat NO -728/2, Bldg No -A6 | 36 | 36 |
| Gat No -728/2, Bldg No -A7 | 36 | 36 |
| Gat No -728/2, Bldg No -A8 | 36 | 36 |
| Gat NO 728/2, Bldg NO -A9 | 36 | 36 |
| Gat No -728/2, Bldg No-A10 | 36 | 36 |
| Gat No -728/2, Bldg No-A11 | 36 | 36 |
| Gat No -728/2, Bldg No-A12 | 36 | 36 |
| Gat No -729/1, Bldg No A1 | 36 | 36 |
| Gat No -729/1, Bldg No -A2 | 36 | 36 |
| Gat No -729/1, Bldg No -A3 | 36 | 36 |
| Gat No -729/1, Bldg No -A4 | 36 | 36 |
| Gat vNo -729/1, ,Bldg No -A5 | 36 | 36 |
| Gat No -729/1, Bldg No -A6 | 36 | 36 |
| Gat No -729/1, Bldg No-A7 | 36 | 36 |
| Gat No -729/1, Bldg No -A8 | 36 | 36 |
| Gat No -729/1, Bldg No-A9 | 36 | 36 |
| Gat No -729/1, Bld No-A10 | 36 | 36 |
| Gat No -728/2P, Bldg No-A1 | 36 | 36 |
| Gat No -728/2P, Bldg No -A2 | 36 | 36 |
| Gat No -728/2P, Bldg No -A3 | 36 | 36 |
| Gat No -728/2P, Bldg No -A4 | 36 | 36 |
| Gat No 728/2P, Bldg No -A5 | 36 | 36 |
| Gat No 728/2P, Bldg No -A6 | 36 | 36 |
| Gat No -845/5, 845/6, Bldg No -A1 | 36 | 36 |
| Gat No -845/5, 845/6, Bldg No-A2 | 36 | 36 |
| Gat No -845/5, 845/6, Bldg No -A3 | 36 | 36 |
| Gat NO -845/5, 845/6, Bldg No -A4 | 36 | 36 |
| Gat No -845/5, 845/6, Bldg No -A5 | 36 | 36 |
| Gat No -845/5, 845/6, Bldg No -A6 | 36 | 36 |
| Gat No -845/5, 845/6, Bldg No -A7 | 36 | 36 |
| Gat No -707, Bldg No-A8 | 24 | 24 |
| Gat No -707, Bldg No-A9 | 36 | 36 |
| Gat No -707, Bldg No -A10 | 36 | 36 |
| Gat No -707, Bldg No -A11 | 36 | 36 |
| Gat No -707, Bldg No -A12 | 36 | 36 |
| Gat No -707,Bldg No-A13 | 36 | 36 |
| Gat No -707, Bldg No -A14 | 36 | 36 |
| Gat No -707, Bldg No-A15 | 36 | 36 |
| Gat No -707, Bldg No-A16 | 36 | 36 |
| Gat No -707, Bldg No -A17 | 36 | 36 |
| Gat No -707, Bldg No -A18 | 36 | 36 |
| Gat No -707, Bldg No -A19 | 36 | 36 |
| Gat No -707 Bldg No -A20 | 36 | 36 |
| Gat No -707, Bldg No -A21 | 36 | 36 |
| Gat No -707, Bldg No-A22 | 36 | 36 |
| Gat No -707, Bldg No -A23 | 36 | 36 |
| Gat No -707, Bldg No -A24 | 36 | 36 |
| Gat No -707, Bldg No-A25 | 36 | 36 |
| Gat No -707, Bldg No -A26 | 36 | 36 |
| Gat No -707, Bldg No-A27 | 36 | 36 |
| Gat NO -707, Bldg No -A28 | 36 | 36 |
| GAt No -707, Bldg No -A29 | 36 | 36 |
| Gat No -707, Bldg No -A30 | 36 | 36 |
| Gat No -707, Bldg No -A7 | 36 | 36 |
| Gat No -697, Bldg No -A1 | 36 | 36 |
| Gat No -697, Bldg No - A2 | 36 | 36 |
| Gat No -697, Bldg No -A3 | 36 | 36 |
| Gat No -697, Bldg No -A4 | 36 | 36 |
| Gat No -697, Bldg No- A5 | 36 | 36 |
| Gat No -697, Bldg No -A6 | 36 | 36 |
| Gat No -697, Bldg No -A7 | 36 | 36 |
| Gat No -697, Bldg No -A8 | 36 | 36 |
| Gat No -697 ,Bldg No -A9 | 36 | 36 |
| Gat No -697, Bldg No -A10 | 36 | 36 |
| Gat No -697, Bldg No -A11 | 36 | 36 |
| gat No -697, Bldg No -A12 | 36 | 36 |
| Gat No -697, Bldg No -A13 | 36 | 36 |
| Gat No -697, Bldg No -A14 | 36 | 36 |
| Gat No -697, Bldg No -A15 | 36 | 36 |
| Gat NO -697, Bldg No -A16 | 36 | 36 |
| Gat NO -697, Bldg No A17 | 36 | 36 |
| Gat No -697, Bldg No -A18 | 36 | 36 |
| Gat No -697, Bldg No-A19 | 36 | 36 |
| Gat No -697, Bldg No-A20 | 36 | 36 |
| Gat No -697, Bldg No -A21 | 36 | 36 |
| gat No -697, Bldg No -A22 | 36 | 36 |
| Gat No -697, Bldg No-A23 | 36 | 36 |
| Gat No -697, Bldg No -A24 | 36 | 36 |
| Gat No -697, Bldg No -A25 | 36 | 36 |
| Gat no -721/1, Bldg No -A1 | 36 | 36 |
| Gat No -721/1, Bldg No -A2 | 36 | 36 |
| Gat No -721/1, Bldg No -A3 | 36 | 36 |
| gat No -721/1, Bldg No -A4 | 36 | 36 |
| Gat No -721/1, Bldg No -A5 | 36 | 36 |
| Gat No --721/1, Bldg No -A6 | 36 | 36 |
| Gat No -721/1, Bldg No- A7 | 36 | 36 |
| Gat No -721/1, Bldg No -A8 | 36 | 36 |
| Gat No -721/1, Bldg No -A9 | 36 | 36 |
| Gat No -721/1, Bldg No -A10 | 36 | 36 |
| Gat No -721/1, Bldg No -A11 | 36 | 36 |
| Gat No -721/1, Bldg No -A12 | 36 | 36 |
| Gat No -721/1, Bldg No -A13 | 36 | 36 |
| Gat No -721/1, Bldg No -A14 | 36 | 36 |
| Gat No -721/1, Bldg No -A15 | 36 | 36 |
| Gat No -721/1, Bldg No -A16 | 24 | 24 |
| Gat No -721/3, Bldg No -A1 | 24 | 24 |
| Gat No -721/3, Bldg No -A2 | 24 | 24 |
| Gat No -721/3, Bldg No -A3 | 24 | 24 |
| Gat No -721/3, Bldg no -A4 | 36 | 36 |
| Gat No -721/3, Bldg No -A5 | 36 | 36 |
| Gat No -721/3, Bldg No -A6 | 36 | 36 |
| Gat No -721/3, Bldg No-A7 | 36 | 36 |
| Gat No -721/3, Bldg No -A8 | 36 | 36 |
| Gat No -721/3, Bldg No -A9 | 36 | 36 |
| Gat No -721/3, Bldg no -A10 | 36 | 36 |
| Gat no -721/3, Bldg No -A11 | 36 | 36 |
| gat No -721/3, Bldg No -A12 | 36 | 36 |
| Gat no -721/3, Bldg no -A13 | 36 | 36 |
| Gat No -721/3, Bldg no -A14 | 36 | 36 |
| Gat no -721/3, bldg No -B1 | 36 | 36 |
| Gat No -755/1, Bldg No -A1 | 36 | 36 |
| gat No -755/1, Bldg No-A2 | 36 | 36 |
| Gat No -755/1, Bldg No-A3 | 36 | 36 |
| gat No -755/1, Bldg No-A4 | 36 | 36 |
| gat no -755/1, Bldg No -A5 | 36 | 36 |
| Gat no -755/1, Bldg No -A6 | 36 | 36 |
| Gat No -755/1, Bldg No-A7 | 36 | 36 |
| Gat No -755/1, bldg No -A8 | 24 | 24 |
| Gat No -755/1, Bldg No-A9 | 24 | 24 |
| Gat No -755/1, Bldg No -A10 | 24 | 24 |
| Gat No -755/1, Bldg No -A11 | 24 | 24 |
| Gat No -755/1,Bldg No -A12 | 24 | 24 |
| Gat No-755/1, Bldg No -A13 | 24 | 24 |
| Gat No-755/1,Bldg No -A14 | 24 | 24 |
| Gat No-755/1, Bldg No -A15 | 24 | 24 |
| Gat No -764/1A/1B/1C/D/1, Bldg No-A1 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A2 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A3 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A4 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A5 | 36 | 36 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No -A6 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A7 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D, Bldg No -A8 | 36 | 36 |
| gat No-764/1A/1B/1C/1D,1, Bldg No -A9 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A10 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A11 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A12 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A13 | 36 | 36 |
| Gat NO -764/1A/1B/1C/1D/1, Bldg No -A14 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A15 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A16 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A17 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A18 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A19 | 36 | 36 |
| Gat No 764/1A/1B/1C/1D/1, Bldg No -A20 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A21 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A22 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A23 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A24 | 36 | 36 |
| Gta nO -764/1A/1B/1C/1D/1, Bldg No -A25 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D, Bldg No -A26 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A27 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A28 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No -A29 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A30 | 36 | 36 |
| Gat NO -764/1A/1B/1C/D/1, Bldg No -A31 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A32 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A33 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A34 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A35 | 36 | 36 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No -A36 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A37 | 36 | 36 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No-A38 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No -A39 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1, Bldg No -A40 | 36 | 36 |
| Gat No -764/1a/1b/1c/1d/1, Bldg No -A41 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No-A42 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1,Bldg No A 43 | 36 | 36 |
| Gat No -764/1A/1B/1C/1D/1 Bldg No -A44 | 36 | 36 |
| Gat No-764/1A/1B/1C/1D/1, Bldg No -A45 | 36 | 36 |
| Gat No-764/1A/1B/1C/1D/1,Bldg No -B1 | 24 | 24 |
| Gat No 963/1, 963/2, 963/3, 977/1, Bldg No 1 | 36 | 36 |
| Gat No - 845/5, 845/6 Bldg No - A8 | 24 | 24 |
| Gat No 845/5, 845/6 Bldg No - A9 | 36 | 36 |
| Gat No - 845/5, 845/6 Bldg No - A10 | 36 | 36 |
| Gat No - 845/5, 845/6 Bldg No- A11 | 36 | 36 |
| Gat No - 845/5, 845/6 Bldg No - A12 | 36 | 36 |
| Gat No - 845/5, 845/6 Bldg No- A13 | 34 | 34 |
| Gat No 845/5, 845/6 Bldg No- A14 | 36 | 36 |
| Gat No 845/5, 845/6 Bldg No- A15 | 36 | 36 |
| Gat No- 963/1,963/2,963/3, 977/1 Bldg No- 2 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No-3 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No - 4 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 5 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No 6 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 7 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 8 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 9 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 10 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 11 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 12 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 13 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 14 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 15 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 16 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 17 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 18 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 19 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 20 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 21 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 22 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 23 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No - 24 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 25 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No - 26 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 27 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 28 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 29 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 30 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 31 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 32 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 33 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 34 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 35 | 36 | 36 |
| Gat No - 963/1,963/2,963/3,977/1 Bldg No- 36 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 37 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 38 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 39 | 36 | 36 |
| Gat No- 963/1,963/2,963/3,977/1 Bldg No- 40 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 1 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 2 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 3 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 4 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 5 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 6 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 7 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No - 8 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 9 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 10 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg no- 11 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No - 12 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 13 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No - 14 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg no - 15 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 16 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 17 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 18 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 19 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 20 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg no- 21 | 36 | 36 |
| Gat no- 981/1,982/1,982/2 Bldg No- 22 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 23 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg no- 24 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 25 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 26 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 27 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 28 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 29 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 30 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 31 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 32 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 33 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 34 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 35 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 36 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 37 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 38 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 39 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 40 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 41 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 42 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 43 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 44 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 45 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 46 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 47 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 48 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 49 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 50 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 51 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 52 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 53 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 54 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 55 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 56 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 57 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 58 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 59 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 60 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 61 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 62 | 36 | 36 |
| Gat No 981/1,982/1,982/2 Bldg No- 63 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 64 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 65 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 66 | 36 | 36 |
| Gat No - 981/1,982/1,982/2 Bldg No- 67 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 68 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 69 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 70 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 71 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 72 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 73 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 74 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 75 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 76 | 36 | 36 |
| Gat no- 981/1,982/1,982/2 Bldg No- 77 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 78 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 79 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 80 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 81 | 36 | 36 |
| Gat No- 981/1,982/1,982/2 Bldg No- 82 | 36 | 36 |
| Gat No- 979/1 Bldg No- 1 | 36 | 36 |
| Gat No 979/1 Bldg No- 2 | 36 | 36 |
| Gat No- 979/1 Bldg No- 3 | 36 | 36 |
| Gat No- 979/1 Bldg No- 4 | 36 | 36 |
| Gat No- 979/1 Bldg No- 5 | 36 | 36 |
| Gat No 979/1 Bldg No- 6 | 36 | 36 |
| Gat No - 979/1 Bldg No- 7 | 36 | 36 |
| Gat No- 979/1 Bldg No- 8 | 36 | 36 |
| Gat No- 979/1 Bldg No- 9 | 36 | 36 |
| Gat No- 979/1 Bldg No- 10 | 36 | 36 |
| Gat No- 979/1 Bldg No- 11 | 36 | 36 |
| Gat No- 979/1 Bldg No- 12 | 36 | 36 |
| Gat No- 979/1 Bldg No- 13 | 36 | 36 |
| Gat No- 979/1 Bldg No- 14 | 36 | 36 |
| Gat No- 979/1 Bldg No- 15 | 36 | 36 |
| Gat No- 979/1 Bldg No- 16 | 36 | 36 |
| Gat No- 979/1 Bldg No- 17 | 36 | 36 |
| Gat No- 979/1 Bldg No- 18 | 36 | 36 |
| Gat No 979/1 Bldg No- 19 | 36 | 36 |
| Gat No- 979/1 Bldg No- 20 | 36 | 36 |
| Gat No- 979/1 Bldg No- 21 | 36 | 36 |
| Gat No- 979/1 Bldg No- 22 | 36 | 36 |
| Gat No- 979/1 Bldg No- 23 | 36 | 36 |
| Gat No- 979/1 Bldg No- 24 | 36 | 36 |
| Gat No- 979/1 Bldg No- 25 | 36 | 36 |
| Gat No- 979/1 Bldg No- 26 | 36 | 36 |
| Gat No- 979/1 Bldg No- 27 | 36 | 36 |
| Gat No- 979/1 Bldg No- 28 | 36 | 36 |
| Gat No- 979/1 Bldg No- 29 | 36 | 36 |
| Gat No- 979/1 Bldg No- 30 | 36 | 36 |
| Gat No- 979/1 Bldg No- 31 | 36 | 36 |
| Gat No- 710/1 Bldg No- A1 | 36 | 36 |
| Gat No- 710/1 Bldg No- A2 | 36 | 36 |
| Gat No- 710/1 Bldg No- A3 | 36 | 36 |
| Gat No-710/1 Bldg No- A4 | 36 | 36 |
| Gat No- 710/1 Bldg No- A5 | 36 | 36 |
| Gat No- 710/1 Bldg No- A6 | 36 | 36 |
| Gat No-710/1 Bldg No- A7 | 36 | 36 |
| Gat No- 710/1 Bldg No- A8 | 36 | 36 |
| Gat No - 710/1 Bldg No- A9 | 36 | 36 |
| Gat No- 710/1 Bldg No - A10 | 36 | 36 |
| Gat No- 710/1 Bldg No- A11 | 36 | 36 |
| Gat No- 710/1 Bldg No- A12 | 36 | 36 |
| Gat No- 710/1 Bldg No- A13 | 36 | 36 |
| Gat No- 710/1 Bldg No- A14 | 36 | 36 |
| Gat No- 710/1 Bldg No- A15 | 36 | 36 |
| Gat No- 710/2 Bldg No- A1 | 36 | 36 |
| Gat No- 710/2 Bldg No- A2 | 36 | 36 |
| Gat No- 710/2 Bldg No- A3 | 36 | 36 |
| Gat No- 710/2 Bldg No- A4 | 36 | 36 |
| Gat No-710/2 Bldg No- A5 | 36 | 36 |
| Gat No- 710/2 Bldg No- A6 | 36 | 36 |
| Gat No- 710/2 Bldg No- A7 | 36 | 36 |
| Gat No- 710/2 Bldg No- A8 | 36 | 36 |
| Gat No 710/2 Bldg No- A9 | 36 | 36 |
| Gat No- 710/2 Bldg No- A10 | 36 | 36 |
| Gat No- 755/2 Bldg No- A1 | 36 | 36 |
| Gat No- 755/2 Bldg No- A2 | 36 | 36 |
| Gat No- 755/2 Bldg No- A3 | 36 | 36 |
| Gat No- 755/2 Bldg No- A4 | 36 | 36 |
| Gat No- 755/2 Bldg No- A5 | 36 | 36 |
| Gat No- 755/2 Bldg No- A6 | 36 | 36 |
| Gat No- 755/2 Bldg No- A7 | 36 | 36 |
| Gat No- 755/2 Bldg No- A8 | 36 | 36 |
| Gat No- 755/2 Bldg No- A9 | 36 | 36 |
| Gat No- 755/2 Bldg No- A10 | 36 | 36 |
| Gat No- 755/2 Bldg No- A11 | 36 | 36 |
| Gat No- 755/2 Bldg No- A12 | 36 | 36 |
| Gat No- 755/2 Bldg No- A13 | 36 | 36 |
| Gat No- 755/2 Bldg No- A14 | 36 | 36 |
| Gat No- 755/2 Bldg No- A15 | 36 | 36 |
| L19-435 | 36 | 36 |
| L19-436 | 36 | 36 |
| L19-437 | 36 | 36 |
| L19-438 | 36 | 36 |
| L19-439 | 36 | 36 |
| L19-440 | 36 | 36 |
| L19-441 | 36 | 36 |
| L19-442 | 36 | 36 |
| L19-443 | 36 | 36 |
| L19-444 | 36 | 36 |
| L19-445 | 36 | 36 |
| L19-446 | 24 | 24 |
| L19-447 | 24 | 24 |
| L19-448 | 24 | 24 |
| L19-449 | 24 | 24 |
| L19-450 | 24 | 24 |
| Gat No 722-A3 GF-101 TO 112 FF-201 TO 212 SF- 301 TO 312 | 36 | 36 |
| L-11-233 | 36 | 36 |
Land and ownership1
MahaRERA does not publish landowner contact details. MahaRERA has published no encumbrance declaration for this project. That is silence on the question, and not a record of clear land.
| Landowner | Village | District |
|---|---|---|
| Ray Nagar Housing Co-op Societies Federation Ltd | Solapur (M Corp.) | Solapur |
Approvals and building plan
Project account and cost
70 percent of buyer money must sit in the project account. Account numbers are not published by MahaRERA, so check that your agreement for sale names a designated account for this project and pay into that account only.
Certifying professionals and partners5
Form 1, 2 and 3 certificates from these professionals release the promoter's withdrawals from the 70 percent account.
| Role | Name |
|---|---|
| Architect | Santosh Mote |
| Architect | Pravin Deodhar |
| Architect | Parag Rane |
| Engineer | Shrinivas Mohalkar |
| Engineer | Prakarsh Sangave |
| Partner | Role in project |
|---|---|
| Vasant Vihar Realty Pvt Ltd | - |
Complaints filed with MahaRERA
No complaints on record against this registration.
The permission chain
The permissions a project needs, in the order they happen, matched to MahaRERA's own document slots. A slot on the file means the promoter uploaded a document there; it is not proof the permission was granted, and the filing carries no issue dates. An empty slot is not proof an approval is missing.
- Legal title reportOn the file
A lawyer's report on who owns the land and what is registered against it.
uploaded 6 Apr 2021 - Layout approvalOn the file
The planning authority's approval of how the plots and buildings sit on the land.
uploaded 23 Apr 2024 - Building plan approvalOn the file
Sanction of the building plans themselves, filed as an IOD in Mumbai and as a plan approval elsewhere.
uploaded 23 Apr 2024 - Commencement CertificateOn the file
Permission to begin construction. On a plotted development the same slot carries the NA order instead.
uploaded 23 Apr 2024Confirm the Commencement Certificate covers the specific floor you are buying. - Occupancy CertificateOn the file
The legal go-ahead to move in. It comes at the end, so its absence on a project still under construction is expected.
uploaded 2 May 2024
Documents filed254
As listed on the registration, named by the MahaRERA slot each file was filed under, with the promoter's own file name beneath; the newest 80 of 254 are shown. The files themselves are available at source: open this registration on the MahaRERA portal. We publish what the filing says and never host the promoter's documents in place of it.
| Document | Uploaded |
|---|---|
| Annual Audit Report of Statutory CA (Form 5) (FY 2022-23)File: CA FORM 5 PHASE I MAR 23.PDF | 14 May 2024 |
| Annual Audit Report of Statutory CA (Form 5) (FY 2021-22)File: CA FORM 5 PHASE I MAR 22.PDF | 14 May 2024 |
| Engineers Certificate on Quality Assurance (Form 2A FY 2023-24)File: ARCHITECTS CERTIFICATE-29-04-2024_FORM-4.pdf | 2 May 2024 |
| Occupancy Certificate/ Completion Certificate/ Architect's certificate of completion for plotted developmentFile: OC Gat no 707.pdf | 2 May 2024 |
| Occupancy Certificate/ Completion Certificate/ Architect's certificate of completion for plotted developmentFile: OC LETTER-845-5-845-6.pdf | 2 May 2024 |
| Architect’s Certificate on Completion of Project (Form 4)File: ARCHITECTS CERTIFICATE-29-04-2024_FORM-4.pdf | 2 May 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-31-12-2021.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-31-03-2022.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-30-06-2022.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-30-09-2022.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-31-12-2022.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-31-03-2023.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-30-06-2023.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-30-09-2023.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-31-12-2023.PDF | 24 Apr 2024 |
| Certificates of Architect (Form 1)(Mandatory for only ongoing project)File: FORM 1 ARCHITECTS CERTIFICATE-29-02-2024.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-31-12-2021.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-31-03-2022.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-30-06-2022.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-30-09-2022.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-31-12-2022.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-31-03-2023.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-30-06-2023.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-30-09-2023.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-31-12-2023.PDF | 24 Apr 2024 |
| Engineer’s Certificate on Cost Incurred on Project (Form 2)File: FORM 2 ENGINEERS CERFITICETE-29-02-2024.PDF | 24 Apr 2024 |
| Engineers Certificate on Quality Assurance (Form 2A FY 2019-20)File: FORM 2A QUALITY ASSURANCE-31-12-2021.PDF | 24 Apr 2024 |
| Engineers Certificate on Quality Assurance (Form 2A FY 2020-21)File: FORM 2A QUALITY ASSURANCE-31-03-2022.PDF | 24 Apr 2024 |
| Engineers Certificate on Quality Assurance (Form 2A FY 2021-22)File: FORM 2A QUALITY ASSURANCE-31-03-2023.PDF | 24 Apr 2024 |
| Engineers Certificate on Quality Assurance (Form 2A FY 2022-23)File: FORM 2A QUALITY ASSURANCE-31-03-2023.PDF | 24 Apr 2024 |
| Engineers Certificate on Quality Assurance (Form 2A FY 2022-23)File: FORM 2A QUALITY ASSURANCE-29-02-2024.PDF | 24 Apr 2024 |
| Engineers Certificate on Quality Assurance (Form 2A FY 2022-23)File: FORM 2 ENGINEERS CERFITICETE-29-02-2024.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-DEC-2021.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-MAR-2022.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-JUN-2022.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-SEP-2022.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-MAR-2023.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-JUN-2023.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-SEP-2023.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-DEC-2023.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-FEB-2024.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-DEC-2022.PDF | 24 Apr 2024 |
| Certificates of CA (Form 3)File: FORM-3-FEB-2024.PDF | 24 Apr 2024 |
| Disclosure of Interest in Other Real Estate OrganizationsFile: FORM-3-DEC-2022.PDF | 24 Apr 2024 |
| Other - LegalFile: UNDERTAKING LETTER LEGAL.PDF | 24 Apr 2024 |
| Other - FinanceFile: ENCUMBRANCE LETTER FINANCE.PDF | 24 Apr 2024 |
| Layout approvalFile: 710-1_.pdf | 23 Apr 2024 |
| Layout approvalFile: 710-2.pdf | 23 Apr 2024 |
| Layout approvalFile: 755-2.pdf | 23 Apr 2024 |
| Layout approvalFile: 963.pdf | 23 Apr 2024 |
| Layout approvalFile: 979.pdf | 23 Apr 2024 |
| Layout approvalFile: 981.pdf | 23 Apr 2024 |
| Building plan approval or NA orderFile: 755-2.pdf | 23 Apr 2024 |
| Building plan approval or NA orderFile: 845.pdf | 23 Apr 2024 |
| Building plan approval or NA orderFile: 963.pdf | 23 Apr 2024 |
| Building plan approval or NA orderFile: 981_BP.pdf | 23 Apr 2024 |
| Building plan approval or NA orderFile: 979.pdf | 23 Apr 2024 |
| Building plan approval or NA orderFile: 710-1.pdf | 23 Apr 2024 |
| Building plan approval or NA orderFile: 710-2.pdf | 23 Apr 2024 |
| Layout approvalFile: 845-5-6 LAYOUT APPROVAL DRAWING.pdf | 23 Apr 2024 |
| Copy of Layout Approval (in case of layout)File: 845-5-6 LAYOUT APPROVAL DRAWING.pdf | 23 Apr 2024 |
| Copy of Layout Approval (in case of layout)File: 710-1_.pdf | 23 Apr 2024 |
| Copy of Layout Approval (in case of layout)File: 710-2.pdf | 23 Apr 2024 |
| Copy of Layout Approval (in case of layout)File: 755-2.pdf | 23 Apr 2024 |
| Copy of Layout Approval (in case of layout)File: 963.pdf | 23 Apr 2024 |
| Copy of Layout Approval (in case of layout)File: 979.pdf | 23 Apr 2024 |
| Copy of Layout Approval (in case of layout)File: 981.pdf | 23 Apr 2024 |
| Building Plan Approval (IOD)File: 755-2.pdf | 23 Apr 2024 |
| Building Plan Approval (IOD)File: 845.pdf | 23 Apr 2024 |
| Building Plan Approval (IOD)File: 963.pdf | 23 Apr 2024 |
| Building Plan Approval (IOD)File: 981_BP.pdf | 23 Apr 2024 |
| Building Plan Approval (IOD)File: 979.pdf | 23 Apr 2024 |
| Building Plan Approval (IOD)File: 710-1.pdf | 23 Apr 2024 |
| Building Plan Approval (IOD)File: 710-2.pdf | 23 Apr 2024 |
| Commencement Certificates / NA Order for plotted developmentFile: PLINTH CC GAT NO 979-1.PDF | 23 Apr 2024 |
| Commencement Certificates / NA Order for plotted developmentFile: PLINTH CC GAT NO - 981, 982.PDF | 23 Apr 2024 |
| Commencement Certificates / NA Order for plotted developmentFile: FURTHER CC GAT NO 845-5, 845-6.PDF | 23 Apr 2024 |
| Commencement Certificates / NA Order for plotted developmentFile: FURTHER CC GAT NO 710-1.PDF | 23 Apr 2024 |
| Commencement Certificates / NA Order for plotted developmentFile: FURTHER CC GAT NO 710-2.PDF | 23 Apr 2024 |
| Commencement Certificates / NA Order for plotted developmentFile: FURTHER CC GAT NO 755-2.PDF | 23 Apr 2024 |
Comparing a few projects?
You have opened several on ReraGenie. A free account keeps them in one list with their booking and possession figures, and puts two to six of them side by side.
How this compares with Solapur
Computed across the 550+ Solapur projects on ReraGenie, from their own filings.
Buyer report
Useful on a completed registration when you are buying resale, or checking what was promised against what was delivered.
- Red flags and clear checks, the possession story, sanctions and sales, land and title, who you are dealing with
- Joined against the promoter's 1 other registration and every project registered within 2 km, which the RERA portal never shows together
- All 254 filed documents as one ZIP, foldered, with a manifest
Keep Ray Nagar Housing Project on your shortlist
Saving puts this project on your dashboard with its booking and possession figures, ready to place side by side with up to five others. A free account also gets our weekly market digest by email.
Other projects near Kumbhari to Doddi road550+ in Solapur
Shhraddha Emrald
Shhraddha Buildcons
Mahanandi Heights
Sneharika Vijayshree Developers
HMEMPIRE210211
HERIYTAGE MANIYDHARI EMPIRE
BRAMHA GALAXY
BRAMHA BUILDCON
Shree Vasundhara Heights
Kishor Rajendra Sanjekar
Panchganga Bramhaputra Heights
HANMANTU KOMARAYYA BURA
See every Solapur project, with the district possession charts
Builder: Vasant Vihar Realty Pvt Ltd
Vasant Vihar Realty Pvt Ltd has 2 registrations on MahaRERA, including Ray Nagar Housing Project and Ray Nagar Housing Project Phase 2. Its filings disclose no earlier MahaRERA projects. Read the full track record. See more projects on the Solapur district page.
Frequently asked questions
What are my rights if Ray Nagar Housing Project is delayed beyond 30 Dec 2025?
Under section 18 of the RERA Act you may stay in the project and claim interest for every month of delay, or exit and claim a full refund with interest. In Maharashtra the rate is SBI's highest MCLR plus 2 percent, currently 10.90% per annum (June 2026). The free delay interest calculator on ReraGenie puts a rupee figure on any delay. Claims are filed as MahaRERA complaints with a Rs 5,000 fee.
How do I verify and contact the developer of Ray Nagar Housing Project?
The registered promoter entity is Vasant Vihar Realty Pvt Ltd, a company as per the filing. Neither this filing nor this promoter's other MahaRERA registrations disclose a CIN, LLPIN or GSTIN for this entity. Your agreement for sale must name this exact entity, not a group brand name. The promoter's registered address and contact details are on the project's MahaRERA listing (scan the QR code on any advertisement) and in its filed documents. The Rs 499 buyer report includes all of them as a single ZIP, foldered by type.
Is my payment protected in Ray Nagar Housing Project?
Partly, by law. 70 percent of every buyer payment must go into the project's designated bank account, withdrawable only against architect, engineer and CA certificates as construction progresses; since July 2024 MahaRERA requires a three-account structure for collections. Separately, a promoter cannot take more than 10 percent of the price before signing a registered agreement for sale (section 13). Neither rule guarantees completion; they limit how far your money can travel from the project.
How current is the construction progress shown for Ray Nagar Housing Project?
Promoters must file a quarterly progress report within 20 days of each quarter end, certified by the architect (Form 1), engineer (Form 2) and chartered accountant (Form 3). The figures above come from the latest filing, so they can trail the site by up to a quarter. A promoter who stops filing QPRs altogether invites penalties under section 61, and a stale filing date is itself a warning sign worth checking on the portal.
Who certifies construction progress at Ray Nagar Housing Project?
The professionals named in the filing: Architect: Santosh Mote; Architect: Pravin Deodhar; Architect: Parag Rane; Engineer: Shrinivas Mohalkar; Engineer: Prakarsh Sangave. Their Form 1 (architect), Form 2 (engineer) and Form 3 (chartered accountant) certificates are what unlock the promoter's withdrawals from the 70 percent account, so their names on record are part of the project's accountability chain.
What should I check before booking in Ray Nagar Housing Project?
Four things this page cannot decide for you: that the carpet area in your agreement matches the filed carpet area (the model agreement allows only a 3 percent variation, with a refund right below that); that the agreement follows MahaRERA's model clauses with deviations highlighted; the promoter's record on their other projects, not just this one; whether construction progress keeps pace with sales in the coming quarters. The Rs 499 buyer report works through all of them from the filings.
Get the buyer report · Rs 499 See a real one first
Studying this micro-market rather than buying a flat? The developer project analysis, Rs 2,999, maps every registration within 5 km from filed coordinates, reads what this market absorbs, prices the parcel and takes the promoter's whole book apart. See a complete sample.
Spotted something wrong on this page, or want to tell us what would make it more useful? Every page here is built from what the promoter filed on MahaRERA, and we read every report.
Report an error Share feedback